Pyronix PCX 256 Manual do Utilizador Página 9

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 17
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 8
PCX User Manual
RINS459-2 7
Section 3: Advanced Functions
3.1 Chime Function
The C key can be used to select the Chime function while the system is disarmed. If enabled, a tone will sound every
time an entry / exit door is opened.
Whilst enabled, a ‘C’ will show on the keypad display.
D
C
B
A
PYRONIX
Time 02:30 c
3.2 Deliberately Omitting a Zone
If a zone has been programmed as ‘Omittable’ by your installer, you can leave this zone unarmed whilst arming the
rest of the zones in that partition. Follow the procedure below:
1. Enter your PIN code or present your tag, and press the
key. The system starts to arm. Press the key
again. The display shows:
D
C
B
A
Omit zones? [01]
2. Enter the zone you wish to omit. Always remember to use a leading zero for zones 01 – 09. The display shows:
D
C
B
A
Omit zones [02]
Zone 02
3. The system will now wait 10 seconds for any additional zones to be entered. After 10 seconds the arming
procedure will continue, and the entry / exit tone will sound. Exit the building as normal.