Pyronix PCX 256 Manual de Instalação Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 72
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 25
PCX 256 PROGRAMMING MANUAL
RINS868-6 Page: 25
5.7.5 Access Control
The following programming shows how to set up the Access Control facility if you are using it. Also
the same programming process applies to ‘Entry Control’ which allows a tag reader to control an
entry point.
Visual Keypad Programming Procedure
ASSIGN KEYPADS/READERS
Access Control
Assign Keypads/Readers
Using the and keys, scroll to ‘ASSIGN
KEYPADS/READERS?
Press the key
Address
Enter the address of the keypad/reader you wish
to assign. Press the key
Type
Enter : for Reader
Press the key
Reader Is
Enter : for Access Control
Press the key
Enter the Lock Open Time (max: 250 seconds).
This is the time the door release is going to be
active when a valid tag’s presented.
Press the key.
Enter the Door Open Time (max: 250 seconds).
This is the time the door is allowed to be open
before triggering an alarm.
Press the key.
Vista de página 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 71 72

Comentários a estes Manuais

Sem comentários